You are currently viewing our podiatry forum as a guest which gives you limited access to view all podiatry discussions and access our other features. By joining our free global community of Podiatrists and other interested foot health care professionals you will have access to post podiatry topics (answer and ask questions), communicate privately with other members, upload content, view attachments, receive a weekly email update of new discussions, access other special features. Registered users do not get displayed the advertisements in posted messages. Registration is fast, simple and absolutely free so please, join our global Podiatry community today!

  1. Have you considered the Clinical Biomechanics Boot Camp Online, for taking it to the next level? See here for more.
    Dismiss Notice
Dismiss Notice
Have you considered the Clinical Biomechanics Boot Camp Online, for taking it to the next level? See here for more.
Dismiss Notice
Have you liked us on Facebook to get our updates? Please do. Click here for our Facebook page.
Dismiss Notice
Do you get the weekly newsletter that Podiatry Arena sends out to update everybody? If not, click here to organise this.

Inter-lab Variation of orthoses

Discussion in 'Biomechanics, Sports and Foot orthoses' started by LCG, May 23, 2009.

  1. LCG

    LCG Active Member


    Members do not see these Ads. Sign Up.
    Hi Guys,
    I was wondering if there are any studies out there that compare standard orthoses between Labs. Ie does a standard 4 degrees poly root device from one lab have the same kinematic results when compared to another 4 degree poly root device from a different lab when all other factors are equal ( namely the negative cast or scan, footwear and subject)
    I seem to see a huge difference in labs when clinically comparing devices and was wondering if this translates to a measurable biomechanical difference.
    Regards
    LCG
     
  2. Now that would be a good study....showing the difference in shapes and mechanical characteristics of orthoses (i.e. arch deformation stiffness, frontal plane rotational stiffness) made off the same foot and ordered exactly the same way from one foot orthosis lab to another!!
     
  3. It would be would'nt it!

    Even just examining the morphological differences of the post "correction" Casts would be a start! I don't know, but I'd bet at least £2.49 that the amount / nature of the cast corrections varies a good deal!

    Be a pricey study though ;-)

    Robert
     
  4. add to the study whether the cast cerforming was done by left or right handed person, when compairing left and right device from the same lab.


    MichaelWeber
     
  5. This is a study I've wanted to see for many, many years.

    The use of a scanned foot would remove any variability in the cast that the labs are working from. This does however, limit the study to CAD /CAM enabled labs. You then need to analyse the variation in the finished devices. I seem to recall Kevin and I discussed this in another thread.
     